EcoSEC GPC/SEC System
TSK-GEL Columns
,,,,,,,,,,,,,,,

TSK-GEL columns
Semi-Micro vs. Conventional
Reference Column

Semi-Micro vs. Conventional TSK-GEL Columns



Benefits of semi-micro columns


The columns of choice for use with the EcoSEC GPC system are referred to as semi-micro columns (dimensions are smaller than conventional columns in terms of internal diameter as well as length: 4.6 mm or 6 mm ID x 15 cm L).

Semi-micro column dimensions are advantageous in terms of shorter analysis time (more samples analyzed per unit time), lower solvent consumption and reduced solvent disposal cost. The EcoSEC GPC system is designed to achieve these benefits. Other GPC systems must be optimized with respect to delay or dead volume as this results in extra-column peak broadening, thus lowering resolution, accuracy and precision.

Minimal extra-column band broadening is required to take full advantage of the highest efficiency GPC columns available. The EcoSEC GPC system uses state of the art fluidics and an innovative design that results in low dead volume. Together with a small stroke volume pump and a 2.5 µL RI flow cell, the EcoSEC GPC system delivers short analysis times, excellent reliability and low operating cost. Semi-micro TSK-GEL GPC columns, 4.6 mm ID x 15 cm L, are at the heart of the EcoSEC GPC system.


Effect of system dead volume

Effect of system dead volume


Column:  TSKgel SuperHZ2000 (4.6 mm ID x 15 cm L x 4)
Eluent: THF
Flow rate:  0.35 mL/min
Temp.: 40°C
Detection: RI
Sample: polystyrene oligomer (MW-500)
Inj.Vol.: 10 µL (0.2 g/L)
      

  
 TSK-GEL columns for polymers soluble in polar organic solvents

Semi-micro columns (6 mm ID x 15 cm L)

 TSK-GEL SuperAW line

Conventional columns (7.5 mm ID x 30 cm L)

 TSK-GEL Alpha columns


TSK-GEL columns for polymers soluble in organic solvents

Semi-micro columns (4.6 or 6 mm ID x 15 cm L)

 TSK-GEL SuperMultiporeHZ line 
 TSK-GEL SuperHZ line for ultra-low adsorption characteristics
 TSK-GEL SuperH line for low adsorption characteristics; max. temp. 140ºC

Conventional columns (7.8 mm ID x 30 cm L)

TSK-GEL Hxl columns for ultra-low adsorption characteristics
TSK-GEL Hhr columns for low adsorption characteristics; max. temp. 140ºC


Our flagship TSK-GEL SW-type columns for the analysis of proteins, and the TSK-GEL PW-type columns for analyzing water-soluble polymers can be found here.

To find out which TSK-GEL column best  suits your SEC analysis, visit the Tosoh Bioscience Website.

Tosoh Bioscience GmbH Zettachring 6, 70567 Stuttgart, Germany  Tel: +49-711-132570  Email: info.tbg@tosoh.com